The PCAN-PCI/104-Express FD allows the connection of PCI/104-Express systems to CAN and CAN FD buses. The PCI/104-Express specification establishes PCI Express for the PC/104 form factor wherewith up to four cards can be stacked. Based on this, standardized modular embedded systems such as industrial PCs can be realized. The CAN bus is connected via 9-pin D-Sub connectors to the supplied slot brackets. There is a galvanic isolation between the computer and the CAN side up to 500 Volts. The card is available as a single, dual, or four-channel version.

The monitor software PCAN-View and the programming interface PCAN-Basic for the development of applications with CAN connection are included in the scope of supply and support the new standard CAN FD.

  • PCI/104-Express card, 1 lane (x1)
  • Up to four cards can be used in one system
  • 1, 2, or 4 High-speed CAN channels (ISO 11898-2)
  • Complies with CAN specifications 2.0 A/B and FD
  • CAN FD support for ISO and Non-ISO standards switchable
  • CAN FD bit rates for the data field (64 bytes max.) from 20 kbit/s up to 12 Mbit/s
  • CAN bit rates from 20 kbit/s up to 1 Mbit/s
  • Connection to CAN bus through D-Sub slot bracket, 9-pin (in accordance with CiA® 303-1)
  • FPGA implementation of the CAN FD controller and Microchip CAN transceiver MCP2558FD
  • Galvanic isolation on the CAN connection up to 500 V, separate for each CAN channel
  • CAN termination can be activated through a solder jumper, separately for each CAN channel
  • 5-Volt supply to the CAN connection can be connected through a solder jumper, e.g., for external bus converter
  • PCIe data transfer via bus master DMA and DMA memory access operations with 32- and 64-bit addresses
  • Extended operating temperature range from -40 to 85 °C (-40 to 185 °F)
  • Optionally available: PCI-104 stack-through connector

PEAK-System offers a wide range of CAN interfaces including device drivers and programming interfaces for Windows® and Linux systems.